Temporary accommodation inspection checklist: what the law and the Code of Guidance require
By M Saeed, Founder, Evidix
In short
Temporary accommodation must be suitable, and in deciding that a council must have regard to Parts 9 and 10 of the Housing Act 1985 and Parts 1 to 4 of the Housing Act 2004 (Housing Act 1996, section 210). The Homelessness Code of Guidance says that, as a minimum, all accommodation should be free of Category 1 hazards. Where a private landlord provides it as a private rented sector offer or as relief accommodation, the 2012 Suitability Order lists ten things that make it unsuitable, from a missing gas safety record or EPC to an unlicensed HMO.
Temporary accommodation is checked against more rules than most people expect, and they come from several places: the Housing Act 1996, the Homelessness Code of Guidance, two Suitability Orders, and the safety regulations that apply to any rented home. This guide puts them in one place, in the order an inspection would follow, with each rule quoted from its source. A free printable checklist is at the end.
It covers England. It is written for councils' placement and procurement teams, and for the landlords, agents and providers who supply temporary accommodation.
Which rules decide whether temporary accommodation is suitable?
The starting point is section 210(1) of the Housing Act 1996:
“In determining for the purposes of this Part whether accommodation is suitable for a person, the local housing authority shall have regard to Parts 9 and 10 of the Housing Act 1985 (slum clearance and overcrowding) and Parts 1 to 4 of the Housing Act 2004.”
Parts 1 to 4 of the 2004 Act include the Housing Health and Safety Rating System (HHSRS) and HMO licensing. The Homelessness Code of Guidance, chapter 17, sets the minimum: “housing authorities should, as a minimum, ensure that all accommodation is free of Category 1 hazards.”
The Code also advises a visit before a private rented property is used: “housing authorities are advised to ensure it is visited by a local authority officer.”
When a private landlord provides it: ten things that make it unsuitable
Article 3 of the Homelessness (Suitability of Accommodation) (England) Order 2012 applies to private rented sector offers, final offers made by a private landlord, and accommodation secured under the prevention and relief duties (sections 189B(2) and 195(2)) under a tenancy with a private landlord. In those cases the accommodation “shall not be regarded as suitable” where:
- the authority is of the view that it is “not in a reasonable physical condition”;
- electrical equipment supplied with it does not meet Schedule 1 to the Electrical Equipment (Safety) Regulations 2016;
- the landlord “has not taken reasonable fire safety precautions with the accommodation and any furnishings supplied with it”;
- the landlord “has not taken reasonable precautions to prevent the possibility of carbon monoxide poisoning”;
- the landlord is not a fit and proper person;
- it is an HMO that needs a mandatory licence (section 55 of the 2004 Act) and is not licensed;
- it is an HMO under an additional licensing scheme (section 56) and is not licensed;
- it does not have a valid energy performance certificate;
- it does not have a current gas safety record under regulation 36 of the Gas Safety (Installation and Use) Regulations 1998;
- the landlord has not provided a written tenancy agreement that the authority considers adequate.
Gas, electrics and alarms: do they apply to licences?
Much temporary accommodation is let on licence, not a tenancy. The safety rules still reach it, with one narrow exception.
Gas. Regulation 36 of the 1998 Gas Safety Regulations defines the landlord, “where the relevant premises are occupied under a licence”, as “the licensor”.
Electrics. The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 are made under section 122 of the Housing and Planning Act 2016, where a “tenancy” “includes a licence to occupy”. The landlord must ensure every installation is inspected and tested by a qualified person “at intervals of no more than 5 years” and “before the specified tenancy commences” (regulation 3).
Alarms. Under regulation 4(1) of the Smoke and Carbon Monoxide Alarm (England) Regulations 2015, a smoke alarm must be “equipped on each storey of the premises on which there is a room used wholly or partly as living accommodation”, and a carbon monoxide alarm “in any room of the premises which is used wholly or partly as living accommodation and contains a fixed combustion appliance other than a gas cooker”. Alarms must be checked on the day a new tenancy begins and repaired or replaced when reported faulty. For these regulations, the Energy Act 2013 says “tenancy” includes any “licence”.
The exception: hostels and refuges. Both the 2020 Electrical Regulations and the 2015 Alarm Regulations exclude a hostel or refuge. The definition of a “hostel” is narrow. It must provide residential accommodation “otherwise than in separate and self-contained premises”, with board or facilities to prepare food, and it must be managed by a private registered provider of social housing, by a voluntary organisation or charity, or be “not operated on a commercial basis” with its costs met in whole or part by government or a local authority. Commercially run, nightly-paid accommodation does not meet that definition.
Fire safety
For buildings with common parts, the Code of Guidance notes that the Regulatory Reform (Fire Safety) Order 2005 “places a duty on landlords” to carry out a fire risk assessment. Check that there is a current one, that its actions have been done, and that escape routes are clear. Inside each unit, the Suitability Order's tests above (fire safety precautions, furnishings, carbon monoxide) apply where a private landlord provides it.
HMOs
If the property is a house in multiple occupation, check whether it needs a licence (mandatory under section 55, or under an additional scheme under section 56), that the licence is in place, and that the number of households is within it. An unlicensed licensable HMO is not suitable as a private rented sector offer.
Space and crowding
Section 210 brings in Part 10 of the Housing Act 1985 on overcrowding. The Code of Guidance says: “Any breach of the room and space standards under Part 10 is likely to constitute a Category 1 hazard.” Record the rooms, their sizes and who is placed in each.
B&B for families
B&B accommodation “is not to be regarded as suitable for an applicant with family commitments” when provided under the main homelessness duties (Homelessness (Suitability of Accommodation) (England) Order 2003, article 3). The exception is where no other accommodation is available, and then only for a period, or total of periods, that “does not exceed 6 weeks” (article 4). Accommodation owned or managed by a council, a registered social landlord or a voluntary organisation is not “B&B accommodation” under the Order.
What is coming: Awaab's Law for licences
Awaab's Law already applies to social landlords' tenancies. The government is consulting on extending it to “temporary accommodation for homeless households” occupied under licence, alongside supported housing and care leaver accommodation; responses close at 11.59pm on 18 December 2026. See Awaab's Law for private rentals and licences.
The inspection checklist
Before a placement, and at each routine visit, record:
- Documents: gas safety record (if there is gas), electrical installation report and its date, EPC, fire risk assessment for common parts, HMO licence (if licensable), the occupation agreement.
- Alarms: a smoke alarm on each storey with living accommodation; a carbon monoxide alarm in each living room with a fixed combustion appliance other than a gas cooker; tested on the day of arrival.
- Category 1 hazards, room by room: damp and mould, excess cold, fire, electrical, falls, structural problems, hygiene and pests.
- Fire: the fire risk assessment's actions done, escape routes clear, fire doors closing, and the fire safety of any furnishings supplied.
- Space: rooms, sizes and occupants against Part 10.
- Family placements in B&B: the date the family arrived, and the running total against six weeks.
- Evidence: dated photos and notes for every item, and who checked it.
Download the printable version below. If you inspect on a phone, Evidix records each item with photos and the date as you go, even with no signal: see field capture.
Get the Temporary accommodation inspection checklist (PDF)
Documents, alarms, Category 1 hazards room by room, space and B&B limits: what to check before a placement and at each visit, with the rule behind each line.
Try Evidix free
Evidix keeps the deadlines, the records and the evidence behind them in one place. 14-day free trial on every plan; plans from £30 a month.
Questions
- Does temporary accommodation need a gas safety record?
- Where there are gas appliances, yes. The landlord's duties in regulation 36 of the Gas Safety (Installation and Use) Regulations 1998 apply where premises are occupied under a licence as well as under a lease: “where the relevant premises are occupied under a licence, the licensor”. And a private rented sector offer is not suitable if the property has no current gas safety record (Suitability Order 2012, article 3(1)(i)).
- Do the smoke and carbon monoxide alarm rules apply to licences?
- Yes, generally. The 2015 Alarm Regulations apply to a “specified tenancy”, and the Energy Act 2013 says “tenancy” includes any “licence”. A hostel or refuge, as the regulations define them, is excluded.
- Do hostels need an electrical inspection every five years?
- Not under the Electrical Safety Standards Regulations 2020, which exclude a hostel or refuge. But the definition is narrow: a “hostel” must be shared, provide board or cooking facilities, and be run by a registered provider, a voluntary organisation or charity, or on a non-commercial, publicly funded basis. Commercially run nightly-paid accommodation is not a hostel under that definition.
- How long can a family stay in B&B accommodation?
- B&B accommodation is not suitable for an applicant with family commitments (Homelessness (Suitability of Accommodation) (England) Order 2003, article 3), unless no other accommodation is available and the family is there for no more than six weeks in total (article 4).
- Does Awaab's Law apply to temporary accommodation?
- Only where it is social housing let by a social landlord on a tenancy. The government is consulting on extending Awaab's Law to temporary accommodation for homeless households let on licence; the consultation closes at 11.59pm on 18 December 2026.
Sources
- Housing Act 1996, section 210 (suitability of accommodation)
- MHCLG: Homelessness code of guidance for local authorities, chapter 17 (suitability of accommodation)
- Homelessness (Suitability of Accommodation) (England) Order 2012, article 3
- Homelessness (Suitability of Accommodation) (England) Order 2003
- Gas Safety (Installation and Use) Regulations 1998, regulation 36
- Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020
- Smoke and Carbon Monoxide Alarm (England) Regulations 2015
- Energy Act 2013, section 150
- Housing and Planning Act 2016, section 122
- MHCLG: Extending Awaab's Law to private rented tenancies and to licences (consultation)
Related
- Supported housing licensing: what the draft regulations require, and how to respond by 10 December
Draft regulations for licensing supported exempt accommodation in England, under the Supported Housing (Regulatory Oversight) Act 2023: who needs a licence, the exemptions, the licence conditions, what a council can ask for, and how to respond by 10 December 2026.
- What is supported exempt accommodation? The definition, Housing Benefit, and what licensing changes
Supported exempt accommodation in England, for the organisations that provide and manage it: the definition in the 2023 Act and the Housing Benefit rules, the four kinds of specified accommodation, why rent is paid through Housing Benefit rather than Universal Credit, and what licensing will change.
- Awaab's Law Phase 2: the new hazard groups, with examples and timescales
From 30 November 2026, Awaab's Law covers significant hazards from excess cold and heat, falls, structural collapse, fire and explosions, electricity and domestic hygiene. What each group covers, how to tell emergency from significant, and what stays out.